26 I
I - 3 Milling Specific Operations
To preset the location for Hole 2:
Press the PRESET soft key.
Press the X axis key.
Enter nominal position value for hole 2: X = 1.5”, mark your input as
an incremental dimension, press the I soft key.
Press the Y axis key.
Enter nominal position value for hole 2: Y = 1.5”, mark your input as
an incremental dimension, press the I soft key.
Press ENTER.
Traverse the X and Y axes until the display value is zero. The square
in the near zero warning is now centered between the two
triangular marks.
To preset the Z axis:
Press the PRESET soft key.
Press the Z axis key.
Press the ENTER key (use last entered preset).
Drill hole 2: Traverse Z axis until the display value is zero. The
square in the near zero warning is now centered between the two
triangular marks.
Retract the drill.
1/2 Soft Key
The 1/2 soft key is used to find the centerline (or midpoint) between
two locations along a selected axis of a workpiece. This can be
performed in either Actual Value or Distance-To-Go mode.
This feature will change datum locations when in Actual
Value mode.